当前位置: 首页 > 产品中心 > 美国 Fluke - 计量校准,校验 > Fluke - 校准器 标准源

产品分类

product categories
Ceyear 思仪 - 测试与测量仪器
德国 R&S - 射频 微波 毫米波
德国 R&S - 示波器 和 探头
德国 R&S - 无线电监测与定位
德国 R&S - 空中安全通信
德国 R&S - 电磁兼容(EMC)测试
美国力科 - 高端示波器、通用
同惠电子 - 测试与测量
同惠 - 阻抗分析仪、LCR电桥
同惠 - 飞安表、皮安表、万用表
同惠 - 电气安规测试仪器
美国 Fluke - 测试与测量
美国 Fluke - 计量校准,校验
德国 罗森伯格 - 测试与测量
美国 CMT - 矢网、扩展、附件
德国 EA - 电源与电子负载
日本日置 HIOKI - 测试仪器
其它仪器仪表

低相位噪声射频基准源 Fluke 96040A

产品名称: 低相位噪声射频基准源 Fluke 96040A
产品型号: Fluke 96040A
产品品牌: 美国 - 福禄克
产品特色:

范    围:1mHz-4GHz

      -130 to +24dBm to 125MHz, 14dBm at 4GHz

分辨率:10µHz0.001dB

准确度:±0.05ppm ± 5µHz

产品概述详细说明附件/软件相关视频用户手册相关应用

Fluke 96040A低相位噪声射频参考标准

Simplify your RF calibration system

The Fluke Calibration Fluke 96040A RF Reference Source enables you to simplify your RF calibration system by replacing many of the instruments and accessories that make up your current system. Its precision signal level and attenuation, high signal purity and precision low distortion modulation make this reference source superior to the general-purpose signal generators that are often used to calibrate spectrum analyzers, modulation meters, RF sensors, attenuators, and similar instruments. Its low phase noise provides superior phase noise performance.

Unlike many RF calibration solutions, the 96040A is designed specifically for RF calibration, with a calibration-oriented user interface that makes it easy to learn and use. The 96040A speeds up calibration procedures, reduces opportunities for operator errors, and greatly simplifies RF metrology. As the core of an RF and microwave calibration system, the Fluke 96040A covers the majority of test points required for calibrating spectrum analyzers of any frequency range.

Automated with MET/CAL® Plus Calibration Management Software, the 96040A reduces complexity and calibration times, dramatically improving efficiency and increasing capacity by 50 % or more over manual methods.

Key benefits

Covers a broad range of RF calibration workload

Reduces the number of instruments and interconnections required for your RF calibration system

“What you set is what you get” accurate signal delivery direct to the UUT input

Integrated 50MHz frequency counter eliminates need for an additional instrument

Calibration-specific interface simplifies technician tasks

Simplifies uncertainty calculations by delivering known signals direct to the unit under test (UUT)

Lowers RF system maintenance costs

With automation, reduces spectrum analyzer calibration times by as much as 50% over manual methods

 

Broad, versatile workload coverage

The Fluke 96040A calibrates a broad workload of RF calibration devices, including:

Spectrum analyzers

Modulation meters and analyzers

RF power meters and sensors

Frequency counters

Attenuators

And more

The metrology associated with calibrating these items becomes simpler because you have fewer error sources and uncertainty contributions to consider.

More than just an RF calibrator

There are many applications in research and development, manufacturing test, and ATE needing better performance than a general purpose signal generator. If wide frequency coverage, frequency resolution, low harmonics, phase noise and spurious content, signal level and attenuation accuracy, or dynamic range are critical parameters the Fluke 96040A is an ideal solution.

Cut the cost of your RF calibration system in half

As the central instrument in a high capability RF spectrum analyzer calibration system, the 96040A can cut your costs in half. The Fluke 96040A replaces all of these parts of a “typical” RF calibration system

Up to four signal sources (from audio/ function generators to RF signal and low phase noise sources)

Power meters and power sensors

Step attenuators

Filters

Pads

Couplers

50MHz frequency counter

 

The Fluke 96040A not only reduces the initial need to purchase, install and configure RF system components, but it also reduces the maintenance and calibration costs associated with all of that equipment. The Fluke 96040A is also easier to transport than a heavy rack of equipment and accessories, making it a good solution for on-site calibration.

With its 4GHz frequency range, the Fluke 96040A performs more than 80 % of all the tests required on high performance, high frequency spectrum analyzers.

For workload items that require frequencies beyond 4GHz, you can use an RF and microwave source that you probably already own alongside the Fluke 96040A to address the few remaining higher frequency test points. For many spectrum analyzer models operating below 4GHz, you only need a Fluke 96040A to perform the entire calibration. You can’t simplify much more than that!

No need for additional function generators

The Fluke 9640A Reference Source’s internal modulation capability makes it suitable for applications that require precision modulation to be applied to the output signal, such as modulation analyzer calibration and spectrum analyzer sweep time testing using an AM signal with more accurate modulation rates. You don’t need additional function generators as a low frequency modulation source—the 96040A delivers it all.

Designed for RF calibration

The Fluke 96040A user interface is designed to simplify processes for calibrating typical items in your workload, such as spectrum analyzers, RF level meters and receivers. Parameter offset, stepping, relative and UUT/DUT error readout modes allow you to work accurately and efficiently, following familiar calibration procedures. You’ll find it easier than ever to determine the performance and tolerances of units under test.

The Fluke 96040A front panel is equipped with dedicated function keys, context-sensitive softkeys, and a bright, easy-to-read color display that make it easy to learn and operate. You can set output levels in terms of power (watts ordBm), voltage (RMS or peak to peak) using familiar multipliers and exponent forms. You can move easily between voltage, power anddBm units without losing entered values or accuracy. In error readout mode to adjust the reading, simply rotate the spin wheel and the UUT error is displayed directly indB, ppm or percent.

The simple, calibration-oriented user interface also makes troubleshooting easier if you encounter an unexpected result or an out-of-tolerance condition while following a manual or automated calibration procedure.

“What you set is what you get” accuracy and signal purity

A rugged, precise levelling head delivers Fluke 96040A signal levels directly to the unit under test (UUT) input just the way you set them on the front panel. This unique “What you set is what you get” feature helps you avoid problems like losses, noise, interference, and mismatch errors, which can be caused by using intermediate connectors and cables. This approach also maintains the integrity of low-level signals. The head maintains signal precision and noise immunity throughout a 154dB dynamic range, down to the very lowest levels at -130dBm.

The leveling head reduces lead changes from 25 to just 5 during a typical calibration, allowing you to “connect once and test many,” extending unattended times in an automated system, and reducing connector wear.

Calibrated as a system to assure system performance

The Fluke 96040A is supplied with a 50 ohm leveling head. The /75 model has both 50 ohm and 75 ohm leveling heads. Each mainframe and head are calibrated together as a complete system. System calibration helps assure overall system performance. Each 96040A instrument is supplied with a comprehensive ISO 17025 compliant certificate of calibration with data for all key parameters, including level and attenuation, output VSWR, and phase noise. You can be assured that your Fluke 96040A is traceable, plus RF metrology and uncertainty analysis become much simpler and faster. Accredited certification is available for the 96040A and both 50 ohm and 75 ohm heads.

State-of-the-art phase noise performance

With reduced low phase noise optimized for low and high offset frequencies and specifications from 1 Hz to 10MHz offsets, the Fluke 96040A offers exceptional phase noise performance beyond that required for today’s high performance workloads.

Phase noise data is included in the Fluke 96040A certificate of calibration. Instead of relying only on the more conservative guaranteed specifications, users have actual performance data for their unit. Even with the best low phase noise signal generators, filters are commonly used during spectrum analyzer phase noise calibration tests, reducing noise levels at wide (high) offset frequencies to improve test margins. The Fluke 9600FLT 1GHz bandpass filter accessory is designed specifically for high performance spectrum analyzer wide-offset phase noise testing and connects easily to 96040A models in either benchtop or rack-mounted applications.

Selectable frequency reference input/ output expands functionality

Selectable external frequency reference input is available as a standard feature on the rear panel of the Fluke 96040A. The input allows you to lock the frequency output to an external reference, such as the Fluke Calibration 910R Rubidium Standard, for applications where high clock accuracy or use of a common reference frequency is important. The frequency reference output allows a UUT to be frequency locked to the Fluke 96040A internal reference clock. This configuration is often required to reduce frequency offset errors that may occur between the reference source and the UUT.

Simplify frequency response tests with 96040A sweep functions

RF applications often require a frequency sweep. The Fluke 96040A’s sweep functions simplify the application of manual legacy spectrum analyzer frequency response testing, as well as filter response measurements.

Automate with MET/CAL® software for “walk-away” efficiency

In a typical automated RF calibration process, the operator must frequently intervene to change test setups, thus limiting the benefits that can be realized by the automation. Walk-away automation can increase calibration system capacity by up to 25 percent using procedures you develop in MET/CAL Plus Calibration Management Software. For example, the manufacturer’s calibration procedure for calibrating the Agilent E4407B 26.5GHz spectrum analyzer requires 27 different and complex test setups. On the other hand, the Fluke 96040A, used with MET/CAL Plus Calibration Management Software, can perform the major core of required tests with a single setup. Only six additional setups would be needed using a MET/CAL procedure.

MET/CAL procedures created by Fluke Calibration for the Fluke 9640A models can be used by the 96040A in 9640A emulation mode. Optimized automated procedures can save time for the operators by allowing them to leave the system running while attending to other work. For example, the E4407B MET/CAL procedure for the legacy 9640A, running in emulation mode on the 96040A, allows for a total 90 minutes of “walkaway” time within the total two-hour calibration runtime.

Using the 96040A with other automation solutions

The Fluke 96040A is also integrated easily into existing automated systems and software. The time savings and efficiency gains offered by the 96040A can be realized by structuring test sequences to take full advantage of its “connect once measure many” capabilities.

The Fluke 96040A is designed to match or exceed the performance and functionality of the HP3335A and HP8662/3A in calibration systems. With HP3335A and HP8662/3A GPIB command emulation as standard, replacing these popular but obsolete and difficult-to-maintain products becomes just a plug-and-play substitution

 

技术指标

Fluke 96040A summary specifications*


Frequency specifications

Level specifications  (50 Ω output, see extended specifications for 75Ω)

Range

1mHz to 4GHz

-130 to +24dBm to 125MHz, 14dBm at 4GHz (leveled)

Resolution

10µHz

0.001dB

Accuracy

±0.05ppm ± 5µHz

Down to -48dBm: ± 0.03dB to 100kHz, ± 0.05dB to 128MHz, ± 0.3dB at 4GHz
  10MHz to128MHz: ±0.05dB to -48dBm, ± 0.1dB to -84dBm , ± 0.7dB at -130dBm

Attenuation


±0.02dB to 49dB, ± 0.15dB at 110dB
  Relative to +10dBm, 10Hz to 128MHz

VSWR

≤100MHz:   ≤1.05, ≤ 2GHz: ≤1.1, 2GHz to 4GHz: ≤1.0 +0.05 xf (GHz)

Harmonics   and spurious

–60dBc   harmonics, –78dBc spurious to 1GHz

Phase   noise at 1GHz

–144dBc/Hz,   typical, at 10kHz to 100kHz offset

Modulation

AM,   FM, PM, internal and external. Frequency pull and external leveling

Frequency   sweep

1MHz   to 4GHz. Linear or Logarithmic. Stop-Start or Center-Span

Frequency   counter

Internal   50MHz frequency counter

Temperature

Operating:   0°C to 50°C, 23°C ± 5°C for specified performance; Storage: -20°C to +70°C.

Standard   interfaces

IEEE-488.2   (GPIB)

GPIB   command emulation

9640A,   9640A-LPN, 9640A-LPNX, HP3335, HP8662A, HP8663A.

Dimensions   (HxWxD)

146   mm x 442 mm x  551 mm (5.8 in x 17.4 in x 21.7 in) including handles   Industry-

standard   19 in (483 mm) rack mounting when fitted with Y9600 rack mounting kit

Weight

18kg   (40 lb)

*Key specifications   summary. Refer to the extended specifications for full and detailed   specifications.

 

型号和配件

型号

描述

Fluke 96040A

4GHz   RF Reference Source including 50Ω Leveling Head

Fluke 96040A/75

4GHz   RF Reference Source including 50Ω and 75Ω Leveling Heads



配件

描述

9600FLT

1GHz   宽偏移相位噪声滤波器

9600CONN

Adapter/Torque   Kit

Y9600

机架安装套件

96000CASE

 Rugged   Transit Case

 